Hydrostatic Test Calculator

Size fill volume and check high-point and low-point pressure for a test section. Defaults are a 508 mm, 6.6 mm WT, Grade 483 metric example. Switch to US Customary to convert those inputs. Results update as you edit.

Results update as you type.

Section 1

Units & Code

Unit system

Switching units converts the numbers already in the form.

Sets the high-point minimum to 1.25 x MOP / MAOP.

Section 2

Pipe & Test Parameters

mm
mm
MPa
m
kPa
kPa

Section 3

Elevation

m
m
m
HighTestLow
Hydrostatic head uses 9.81 kPa per metre between the test point and each elevation.

Section 4

Fill Volume

Inside diameter

494.8 mm

OD minus two wall thicknesses

Fill volume

961.434 m3

Internal area times section length

Bleach dose

961.43 L

1 L per cubic metre

Section 5

Stress & Compliance

100% SMYS yield pressure

12,550.4 kPa

Barlow. SMYS in MPa converted to kPa.

High-point pressure

12,020.6 kPa

Target plus head from test point to high point

Low-point pressure

12,511.1 kPa

Target plus head from test point to low point

1.25 x MOP / MAOP

12,412.5 kPa

Minimum high-point gate used by this tool

High-point gate

High-point pressure at or above 1.25 x MOP / MAOP

Does not meet gate

High-point pressure is 391.9 kPa below 1.25 x MOP / MAOP.

Low-point gate

Low-point pressure at or below 100% SMYS

Meets gate

What this tool calculates

Inside diameter is OD minus two wall thicknesses. In metric, fill volume is internal area times section length in cubic metres, and bleach is 1 litre per cubic metre. In US Customary, fill volume is internal area in square feet times length, converted to barrels at 5.61458 cubic feet per barrel. Bleach gallons follow the prototype conversion from that barrel volume.

Yield pressure is Barlow: 2 x SMYS x WT / OD. Metric SMYS is entered in MPa and converted to kPa. US SMYS is already in PSI. High and low pressures apply 9.81 kPa per metre, or 0.433 PSI per foot, between the test point and each elevation. The only gates shown are high-point pressure at or above the selected-code factor times MOP / MAOP, and low-point pressure at or below 100% SMYS.

Code factors encoded here: CSA Z662 and ASME B31.4 / 49 CFR 195 use 1.25. ASME B31.8 / 49 CFR 192 uses 1.10 for Class 1, 1.25 for Class 2, 1.40 for Class 3, and 1.50 for Class 4. These are the numeric gates in this tool, not a full code review.